Building Features

Precast 4" thick footing pad is provided under all structural columns. Footings shall be placed below the frost penetration level, but in no case less that 46" below adjacent ground.

2Treated Non-Spliced 3-Ply Columns:
The structural columns shall be a nail-laminted assembly consisting of a minimum of three plies of #1 Southern Pine 2x6 or 2x8 lumber treated in accordance with the American Wood Perservers Association Standard, Latest Edition. The exterior plies of the column shall extend without a splice from the footing to the eave height.

3Treated Splash Plank:
A 2x8 Southern Yellow Pine or better splash plank shall extend around the perimeter of the building. All lumber in contract with the ground shall be pressure treated in accordance with the American Wood Preservers Association Standard, Latest Edition. An ACQ barrier material shall be placed between the splash plank and the bottom trim.

4Framing Lumber:
All structural framing lumber shall be #2 or better S4S material and shall bear a stamp indicating species and grade. Material shall be kiln dried to a moisture content of 19% or less.

Roofing and siding panels shall be covered with prepainted galvanized steel trim at all corners, ridge line, intersection of roof and endwalls, intersection of roof and sidewalls and bottom of sidewall steel.

6Closure Strips:
All closure strips shall be laminated polythylene with dovetail and joint; shaped to conform with the roofing and siding profile. Closure strips shall be placed on each side of the ridge, between the ridge, between the ridge cap and roof panel.

7Roofing and Siding:
All roofing and siding material shall be prepainted galvanized steel with a minimum yield strength of 80,000 psi. The panel shall be formed with major structural ribs of 9" o.c. Panels shall be 36" wide to minimize side laps. Roof panels shall be continuous, without end laps, from eave to ridge line, sidewall and endwall shall be continuous without endlap from treated splash plank to the roofline.

Roof panels shall be attached to the roof purlins with annular ringshank nails through the major ribs. Nails shall be 10 gauge steel galvanized with 1 oz. of zinc per foot and each nail shall have a silicone washer not less than .300 inches in diameter and .25 inches thick.
Sidewall panels shall be attached to the framing with color matched galvanized screws with a durable neoprene washer. Sidewall panels shall be attached to the treated splash plank with color matched stainless steel screws with a durable neoprene washer.
Sidewall girts and framing shall be attached to the treated columns with hot dipped galvanized 20d ring shank nails, constructed of quenched, hardened steel or 3.5"x.131" diameter ring shank TLN power driven nails as manufactured by ITW Paslode.

9Light Panels:
All roof and sidewall light panel shall be SunSky corrugated polycarbonate panels, and the panels shall be of the same configuration as the roofing and sidewall panels. Eavelite, Skylite, and Ridgelite shall be White Opal with 45% light transmission and Solar panels shall be Clear with 90% light transmission.

10Slide Doors:
All slide doors shall be constructed with steel horizontals and verticals, and covered with steel panels of the same type as that of the sidewall panels. Both vertical and horizontal members shall be a minimum of 16 gauge steel and not less than 2 1/2" deep. Each door leaf shall be supported with one pair of trolley hangers, which shall ride in an overhead track. Door track shall be 14 gauge; high carbon galvanized steel self cleaning and self aligning supported with galvanized brackets 24" o.c. Trolleys shall have wheels made of Delrin 500R with teflon lubrication. Bottom of doors shall be secured when in the open position with galvanized steel guide rail of length not less than 60% of the width of the door leaf.

All lumber used in the design and construction of wood trusses shall be kiln dried and graded in accordance with current grading rules. Design stresses shall not exceed those listed in the Latest Edition of National Design Specification, Wood Construction and its supplement. Truss plates shall be galvanized steel. Plate and joint design shall conform to the specification as set forth in the latest edition of the Truss Plates Institute's Design Specifications for Metal Plate Connection Wood Trusses. All truss designes must be accompanied by complete drawings bearing the seal of the registered design architect or engineer. Trusses shall bear on the center ply of the laminated column and shall be sandwiched between the outer plies. Trusses shall be nailed and bolted to the columns.